Power On the Server (System Power Button)
->
start /System
Related Information
■
“Power On the Server (System Power Button)” on page 155
■
“Clear a Fault Manually” on page 42
Power On the Server (System Power Button)
Caution -
Do not operate the server without all fans, component heat sinks, air baffles, fillers,
and the cover installed. Severe damage to server components can occur if the server is operated
without adequate cooling mechanisms.
1.
Verify that the power cords are connected and that standby power is on.
Shortly after power is applied to the server, the SP OK/Fault LED blinks as the SP boots. The
SP OK/Fault LED is illuminated solid green when the SP has successfully booted. After the SP
has booted, the Power OK/LED on the front panel begins flashing slowly, indicating that the
host is in standby power mode.
2.
Press and release server power button on the server front panel.
You might need to use a pointed object, such as a pen or pencil.
When main power is applied to the server, the main Power/OK LED begins to blink more
quickly while the server boots and lights solidly once the operating system boots.
Each time the server powers on, POST can take several minutes to complete tests.
Related Information
■
“Power On the Server (Oracle ILOM)” on page 154
■
“Clear a Fault Manually” on page 42
Returning the Server to Operation
155
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...