Servicing the Battery
The battery is located inside the chassis. See
“Internal Component Locations” on page 20
battery maintains system time when the server is powered off and disconnected from AC power.
If the log messages indicate a battery failure, replace the battery.
■
“Replace the Battery” on page 113
Related Information
■
“Detecting and Managing Faults” on page 27
Replace the Battery
Caution -
This procedure requires that you handle components that are sensitive to ESD. This
sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic
practices as described in
.
A customer can perform this procedure. The server must be completely powered down
before performing this procedure. See
“Component Service Categories” on page 49
information about cold-service procedures.
1.
Prepare the host for battery replacement.
To correctly reset the date and time after replacing a battery, you must prevent the host from
automatically powering on, and also disable any NTP server connections. Before you remove
power from the server, perform these steps.
a.
Check the AUTO_HOST_POWER_ON state. At the Oracle ILOM prompt:
->
show /SP/policy HOST_AUTO_POWER_ON
/SP/policy
Properties:
Servicing the Battery
113
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...