Remove the Twelve-Drive Backplane
See
“Removing Power From the Server” on page 50
.
b.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Prevent ESD Damage” on page 54
c.
Extend the server into the service position.
See
“Extend the Server to the Service Position” on page 55
d.
Remove the fan cover.
Remove the three top screws and the two side screws, then remove the cover.
e.
If necessary, remove the fan modules from the server.
See
“Remove a Fan Module” on page 79
.
2.
Pull each drive and filler out far enough to disengage it from the drive backplane.
Note -
You do not need to completely remove the storage drives from the server. Simply
pull them out far enough to disengage them from the drive backplane. If you do remove the
storage drives from the server, record their locations so that you can reinstall them in the same
locations.
136
SPARC S7-2L Server Service Manual • March 2017