Remove the Eight-Drive Backplane
c.
Extend the server into the service position.
See
“Extend the Server to the Service Position” on page 55
d.
Remove the fan cover.
Remove the 12 fan cover screws, then slide the cover forward and lift it off the server.
e.
If necessary, remove the fan modules from the server.
See
“Remove a Fan Module” on page 79
.
2.
Pull each drive out far enough to disengage it from the drive backplane.
Note -
You do not need to completely remove the storage drives from the server. Simply
pull them out far enough to disengage them from the drive backplane. If you do remove the
storage drives from the server, record their locations so that you can reinstall them in the same
locations.
3.
Disconnect the cables from the drive backplane.
a.
Disconnect the two SAS cables from the drive backplane that go to the card
in internal SAS slot 7 (panel 1).
132
SPARC S7-2L Server Service Manual • March 2017