Locate a Failed DIMM (LEDs)
Location from Left to Right
(Seen From Rear)
DIMM Name
Ejector Color
5
/SYS/MB/CMP0/MCU0/CH0/
D1
Black
6
/SYS/MB/CMP0/MCU0/CH0/
D0
White
7
/SYS/MB/CMP0/MCU0/CH1/
D1
Black
8
/SYS/MB/CMP0/MCU0/CH1/
D0
White
9
/SYS/MB/CMP1/MCU1/CH0/
D0
White
10
/SYS/MB/CMP1/MCU1/CH0/
D1
Black
11
/SYS/MB/CMP1/MCU1/CH1/
D0
White
12
/SYS/MB/CMP1/MCU1/CH1/
D1
Black
13
/SYS/MB/CMP1/MCU0/CH0/
D1
Black
14
/SYS/MB/CMP1/MCU0/CH0/
D0
White
15
/SYS/MB/CMP1/MCU0/CH1/
D1
Black
16
/SYS/MB/CMP1/MCU0/CH1/
D0
White
Related Information
■
“DIMM Configuration” on page 93
■
“Locate a Failed DIMM (LEDs)” on page 95
■
“Locate a Failed DIMM (Oracle ILOM)” on page 96
■
“Enable and Verify a DIMM” on page 100
Locate a Failed DIMM (LEDs)
This procedure describes how to identify a faulty DIMM using a button and LEDs on the
motherboard.
Press a button on the motherboard to identify a faulty DIMM.
Servicing DIMMs
95
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...