Find the Server Serial Number
■
Drive filler
■
PCIe filler (covering back panel, not inserted in the PCIe slot)
Caution -
When you remove a server component while the server is connected to power, insert
a new component or filler within 60 seconds to ensure proper system chassis cooling. After
you complete cold-servicing, ensure that all fillers are in place before connecting the server to
power.
Related Information
■
■
“Servicing PCIe Cards” on page 103
■
“Returning the Server to Operation” on page 149
Find the Server Serial Number
You need the serial number of the server's chassis to obtain technical support for the system.
Note -
When a drive backplane or motherboard is replaced, the chassis serial number and part
number might need to be programmed into the new component. This must be done in a special
service mode by trained service personnel.
Locate the serial number using one of the following methods:
■
Read the serial number from a sticker located on the front of the server or
another sticker on the side of the server.
■
At the Oracle ILOM prompt, type.
->
show /System
/System
Targets:
. . .
In the output look for a line under Properties that identifies the product serial number. For
example:
product_serial_number = BDL1026F8F
48
SPARC S7-2L Server Service Manual • March 2017
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...