Verify a Power Supply
“Locate a Faulty Power Supply” on page 87
8.
Verify that the following LEDs are not lit:
■
Service Required LED on the power supply
■
Front and rear Service Required LEDs
■
Rear PS Failure LED on the bezel of the server
“Interpreting LEDs” on page 33
9.
Verify the power supply.
“Verify a Power Supply” on page 91
.
Related Information
■
“Remove a Power Supply” on page 88
■
“Verify a Power Supply” on page 91
Verify a Power Supply
1.
Verify that the amber Service Required LED on the replaced power supply is not
lit.
2.
Verify that the PS Fault LED on the front of the server is not lit.
3.
Use the Oracle ILOM
show faulty
command to verify that the fault has been
cleared.
“Identify Faulted Components” on page 28
for more information on using the
show faulty
command.
Consider these possibilities.
■
If the previous steps did not clear the fault, see
“Detecting and Managing Faults” on page 27
for information about the tools and methods you can use to diagnose component faults.
■
If the previous steps indicate that no faults have been detected, then the component has been
replaced successfully. No further action is required.
Related Information
■
“Locate a Faulty Power Supply” on page 87
■
“Front Panel Components with Eight Drives” on page 11
Servicing Power Supplies
91
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...