Attach Power Cords
If the CMA is in the way, disconnect the left CMA release and swing the CMA open. See
4.
Reconnect the CMA.
Swing the CMA closed and latch it to the left rack rail. Refer to
SPARC S7-2L Server Installation Guide
Related Information
■
“Remove the Server From the Rack” on page 58
■
“Attach Power Cords” on page 154
Attach Power Cords
1.
Attach both power cords to the power supplies.
Note -
As soon as the power cords are connected to a power source, standby power is applied in
the server. Depending on how the firmware is configured, the server might boot at this time.
2.
Power on the server.
See
“Power On the Server (Oracle ILOM)” on page 154
Related Information
■
“Power On the Server (Oracle ILOM)” on page 154
■
“Power On the Server (System Power Button)” on page 155
Power On the Server (Oracle ILOM)
Note -
If you are powering on the server following an emergency shutdown that was triggered
by the top cover interlock switch, you must use the
poweron
command.
Type this command at the Oracle ILOM prompt.
->
poweron
You will see an
alert
message on the system console. This message indicates that the server is
reset. You will also see a message indicating that the VCORE has been margined up to the value
specified in the default
.scr
file that was previously configured. For example:
154
SPARC S7-2L Server Service Manual • March 2017
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...