![Siemens SITRANS LR200 7ML5422 Operating Instructions Manual Download Page 46](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663046.webp)
SITRANS LR200 with mA/HART
46
Operating Instructions, 05/2019, A5E32337676-AE
6.2.1.4
Requesting an Echo Profile
●
In PROGRAM mode, navigate to: Level Meter >Diagnostics (3.) (Page 119) > Echo
profile (3.1.) (Page 119)
●
Press RIGHT arrow
to request a profile.
①
Confidence
⑦
Zoom
②
Distance from Low Calibration Point to vertical cross-
hair
⑧
Measure
③
Algorithm: tF (trueFirst)
⑨
Exit
④
Distance from flange face to target
⑩
Exit icon selected
⑤
Pan left/right - selected
⑪
Exit icon deselected
⑥
Pan up/down
●
Use UP
or DOWN
arrow to scroll to an icon. When an icon is highlighted, that
feature becomes active.
●
To move a cross-hair, press RIGHT
arrow to increase the value, LEFT
arrow to
decrease.
●
To Zoom into an area, position the intersection of the cross-hairs at the center of that
area, select Zoom, and press RIGHT
arrow. Press LEFT
arrow to Zoom out.
●
To update the profile, select Measure and press RIGHT
arrow.
●