![Siemens SITRANS LR200 7ML5422 Operating Instructions Manual Download Page 156](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663156.webp)
SITRANS LR200 with mA/HART
156
Operating Instructions, 05/2019, A5E32337676-AE
A.3
Threaded connection, PTFE rod, external shield
Note
Pressure applications
For pressure applications, it will be necessary to use PTFE tape or other appropriate thread
sealing compound, and to tighten the process connection beyond hand-tight.
①
Nameplate
⑥
Stainless steel antenna shield (inactive length)
②
Sensor reference point
⑦
Stainless steel mounting thread
③
Shield length
SL=min. 100 mm (4") customer-
specified
⑧
Process device tag
④
Overall length
L=374 mm (14.7") plus shield length
⑨
Locking ring
⑤
Active antenna
Dimensions in mm (inch)
* 17 mm (0.67")