![Siemens SITRANS LR200 7ML5422 Operating Instructions Manual Download Page 165](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663165.webp)
SITRANS LR200 with mA/HART
Operating Instructions, 05/2019, A5E32337676-AE
165
A.13
Flange mounting instructions
Note
•
The integral process seal MUST rest on the customer-supplied flange (see the detail
below).
•
The straight/taper transition of the rod should extend past the nozzle/vessel opening. Add
extensions as required
1)
.
①
Wiring access cover
⑦
Process device tag
②
1/2 " NPT or M20 x 1.5 cable entry
⑧
Customer-supplied flange
③
Locking ring
⑨
Integral process seal
④
Customer flanged nozzle to suit
⑩
Nozzle/vessel juncture
⑤
Minimum diameter 2"/DIN 50
⑪
Straight/taper transition
⑥
Vessel
1)
Refer to Rod assembly (Page 166).