![Siemens SITRANS LR200 7ML5422 Operating Instructions Manual Download Page 44](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663044.webp)
SITRANS LR200 with mA/HART
44
Operating Instructions, 05/2019, A5E32337676-AE
Language
Selects the language to be used on the LCD and takes effect immediately.
Options
English, Deutsch, Français, Español
Material
Selects the appropriate echo processing algorithms for the material. See Position detect
(2.8.4.2.) (Page 112) for more detail.
Options
LIQUID
LIQUID LOW DK
1)
(low dielectric liquid – CLEF algorithm enabled)
1)
dK < 3.0
Response Rate
Sets the reaction speed of the device to measurement changes in the target range.
Options
Response Rate (2.4.1.)
Fill rate per Minute (2.4.2.)/Empty rate per Mi-
nute (2.4.3.)
SLOW
0.1 m/min (0.32 ft/min)
MED
1.0 m/min (3.28 ft/min)
FAST
10.0 m/min (32.8 ft/min)
Use a setting just faster than the maximum filling or emptying rate (whichever is greater).
Units
Sensor measurement units.
Options
m, cm, mm, ft, in
Operating Mode
①
Space
④
High Calibration Point (process full level)
②
Level
⑤
Sensor reference point
1)
③
Distance
⑥
Low Calibration Point (process empty level)