![Siemens SITRANS LR200 7ML5422 Operating Instructions Manual Download Page 117](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663117.webp)
SITRANS LR200 with mA/HART
Operating Instructions, 05/2019, A5E32337676-AE
117
Auto false echo suppression range (2.8.7.2.)
Description
Specifies the range within which Learned TVT is used. For more detail, refer to
Auto false echo suppression (2.8.7.1.) (Page 115).
Values
Range: 0.00 to 20.00 m
Factory setting
1.00 m
Related
parameters
Units (2.2.1.) (Page 99)
1.
Calculate range according to Auto false echo suppression (2.8.7.1.) (Page 115) steps 1)
and 2).
2.
Press RIGHT arrow to open Edit mode.
3.
Enter the new value and press RIGHT arrow to accept it.
4.
Set Auto false echo suppression (2.8.7.1.) (Page 115).
Hover level (2.8.7.3.)
Description
Defines how high the TVT (Time Varying Threshold) is placed above the noise
floor of the echo profile, as a percentage of the difference between the peak of
the largest echo in the profile and the noise floor. Refer to Auto false echo sup-
pression (2.8.7.1.) (Page 115) for an illustration.
Values
Range: 0 to 100%
Factory setting
40%
Note
When the device is located in the center of the vessel, the TVT hover level may be lowered
to increase the confidence level of the largest echo.
Shaper mode (2.8.7.4.)
Description
Enables/disables the TVT shaper.
Options
ON
OFF (factory setting)
7.2.7.8
TVT shaper (2.8.8.)
TVT Shaper
Note
•
The range is –100 to 100 bits. With 2 bits per dB this gives a range of –50 to 50 dB.
•
Shaper Mode (2.8.7.4.) must be turned ON in order for TVT shaper points to be
transferred.