Application planning
4.8 Mounting positions and fastening
SIMOTION P350-3 and Panels
90
Manual, 05/2009
4.8.6
Degree of protection
Principles
The degree of protection provided by the front side can only be guaranteed when the
mounting seal lies completely against the mounting cut-out.
CAUTION
Please ensure that the material strength at the mounting cutout does not exceed 6 mm.
Please follow the specifications for the dimensions in the "Mounting cut-out" section.
The degrees of protection are only guaranteed when the following is observed:
•
The material strength at the mounting cut-out is at least 2 mm.
•
The deviation of the evenness of the mounting cutout with an HMI device installed is
≤ 0.5 mm relative to the outside dimensions of the HMI device.
Degree of protection IP65
The IP65 degree of protection is only provided for a clamp mounting together with a ring
seal.
Degree of protection IP54
This degree of protection is provided for screw mounting.