Accessories
9.2 UPS system
SIMOTION P350-3 and Panels
Manual, 05/2009
125
9.2.2
SITOP DC UPS module
The UPS module backs up the power supply for the SIMOTION P using a lead accumulator
module. The back-up time of the battery is several minutes. This gives the user sufficient
time to shut-down the SIMOTION P in an orderly fashion.
%DWWHU\PRGXOH
3RZHUVXSSO\
6,027,213
6,723
'&836PRGXOH
'DWDFDEOH
Input
L+
L+
Input
M
M
9
Output
L+
Output
M
86%
Input
L+
Input
M
9
86%
- Bat
+ Bat
Figure 9-3
Connection of the UPS system / schematic display
There are DIP switches on the UPS module for setting the accumulator switching threshold,
the end-of-charge voltage, the charging current, and the buffering time.
More detailed information about the SITOP DC UPS module appears in the documentation
supplied with the device.
The UPS module uses the USB data interface to forward information to the SIMOTION P;
this can subsequently be displayed with the UPS monitoring application.
$&