Hardware description
3.5 MCI-PN board for SIMOTION P350-3
SIMOTION P350-3 and Panels
56
Manual, 05/2009
Note
The MAC address can be viewed in the device diagnostics of the SIMOTION SCOUT
Engineering System.
The IP address is set using the SIMOTION SCOUT Engineering Software (HW Config).
Label with MAC address
The MAC address of the MCI-PN board is also indicated on a label on the computing unit.
If the MCI-PN board …
then the label indicating the MAC address …
is integrated into a SIMOTION P complete
system,
already affixed underneath the rating plate on the
computing unit's housing.
has been purchased and integrated as an
optional communication module,
affixed to the module on delivery.
Pull the label off the module and stick it to the
computing unit's housing underneath the rating plate.
SYNC I/O interface X8/X9 to the IsoPROFIBUS board X4
The supplied ribbon cable (A5E00447905) is used to connect the two modules. See also
Overview of the SIMOTION P hardware installation (Page 18).
Note
•
The SYNC I/O cable MUST be plugged in when both modules (MCI-PN and
IsoPROFIBUS board) are used.
•
The enclosed battery cable does not serve any purpose when the MCI-PN is used as an
optional board (plugged into slot 2); it is not connected.