Hardware description
3.2 SIMOTION P350-3 PC unit
SIMOTION P350-3 and Panels
38
Manual, 05/2009
3.2.5
7-segment display
The status display consists of two 7-segment displays with two 2-color LEDs.
(1)
LED H2
(2)
LED H1
(3)
2 x 7-segment display
Table 3- 1
Meaning of the 7-segment displays and LEDs
Meaning
SIMOTION operation
BIOS powering up
LED H1
no use assigned
LED H2
(next to the box label)
SIMOTION status
•
Green flashing - RUN
SIMOTION P has started up and is in
RUN mode.
•
Orange flashing - STOP
SIMOTION P has started up and is in
STOP mode.
•
Red flashing/red continuous light
- internal status
The two LEDs light up in two colors (red and
green) in order to test their operation. The two
LEDs switch off when the startup is completed
without errors.
7-segment display 1
Not currently used
(preassigned with "0")
7-segment display 2
(next to the box label)
SIMOTION status (operating status display
for SIMOTION P state)
•
6 - RUNNING
SIMOTION P has started up and the
cyclic tasks are activated.
•
0 to 5, a to f - internal status
The POST codes of the associated test step and
of the operating mode are displayed. The POST
code of the most recently started test step is
displayed when an error occurs. Code 00 is
displayed when the startup is completed without
error.
See also the SIMOTION P350-3 and Panel Fronts Commissioning Manual.