Installation/mounting
5.4 Mounting the SIMOTION panel front
SIMOTION P350-3 and Panels
96
Manual, 05/2009
5.4
Mounting the SIMOTION panel front
5.4.1
Overview of the mounting of SIMOTION panel fronts
With the exception of the SIMOTION P012T variant, the panels can be fastened either with
screws or with clamps. Latch fasteners have to be used for the SIMOTION P012T variant.
IP65 degree of protection can be achieved by using mounting brackets (in conjunction with a
surrounding seal).
Suspended screw mounting ensures only IP54 degree of protection.
Mounting position
The permissible mounting positions depend on the specifications of the attached computer
unit. As a unit with the SIMOTION P350-3, the SIMOTION panel front may be installed in a
vertical position with a maximum inclination of ± 20°.
Dimensioned drawings for the installation can be found in the
SIMOTION P350-3 and Panels
product manual.
5.4.2
Securing with clamps
Scope of validity
Skip this step if you have selected "fasten with screws."
Requirement
●
The mounting cut-out has been completed.
●
Clamps are readily available in the accessories. Clamp and grub screws are included in
the contents of delivery.
Figure 5-5
Clamp assembly