94
System Manual V2 – MOVITRAC® B
5
Explanation of the parameters
Parameters
12_
Analog input AI2 / FBG Setpoint generator (option)
Analog input AI2 is only available with the optional analog module FIO11B.
120
AI2 operating mode
0 / No function
The setpoint at AI2 is not used; the external current limitation is set to
100 %.
1 / 0 ... ±10 V + Setpoint / 100 % corresponds to n
max
The evaluated setpoint at AI2 is added to setpoint 1 (= AI1) observing the
signs; the external current limitation is set to 100 % I
max
.
2 / 0 ... 10 V current limit / 100 % corresponds to I
max
The input serves as external current limitation.
121
Addition FBG setpoint control
module
0 / Off
The unit does not take into account the value from the setpoint generator of
the FBG11 keypad.
1 / ON
The value from the setpoint generator of the FBG11 keypad is added to any
set setpoint source bipolar/fixed setpoint, unipolar/fixed setpoint, RS-485/
fixed setpoint, frequency input/fixed setpoint or SBus/fixed setpoint. The
addition also affects fixed setpoints.
2 / On (without fixed setpoint)
The value from the setpoint generator of the FBG11 keypad is added to any
set setpoint source bipolar/fixed setpoint, unipolar/fixed setpoint, RS-485/
fixed setpoint, frequency input/fixed setpoint or SBus/fixed setpoint. The
addition does
not
affect
fixed setpoints
.
122
Direction of rotation FBG
manual operation
Setting the setpoint with the setpoint generator of the FBG11 keypad in FBG
manual operation.
0 / Unipolar CW
Adjustable speed: 0 ... + n
max
.
1 / Unipolar CCW
Adjustable speed: 0 ... – n
max
.
2 / Bipolar CW and CCW
Adjustable speed: – n
max
... + n
max
.
No.
FBG
Name
Description
Input value
–10 V ... 0 ... 10 V
Normali-
zation
Normalized
input value
–100 % ...
0 ... +100 %
AI2
charact.
curve
Normalized setpoint
–100 % ... 0 ... +100 %
Maximum speed
Speed
setpoint
in rpm
Speed setpoint in %
PI controller actual value in %
P
i
f
kVA
Hz
n
Summary of Contents for MOVITRAC MC07B0037-2A3-4-00