36
System Manual V2 – MOVITRAC® B
4
Technical data of MOVITRAC® B
Technical Data
4.4.15 AC 230 V / 3-phase / size 0L / 1.1 ... 2.2 kW / 1.5 ... 3.0 HP
MOVITRAC
®
MC07B (3-phase supply system)
0011-2A3-4-00
0015-2A3-4-00
0022-2A3-4-00
Part number
828 503 9
828 504 7
828 505 5
INPUT
Rated mains voltage
V
supply
3 × AC 200 ... 240 V
Rated mains frequency
f
supply
50 / 60 Hz ± 5%
Rated mains current, 100 % operation
Rated mains current, 125 % operation
I
supply
I
supply 125
AC 5.1 A
AC 6.3 A
AC 6.4 A
AC 7.9 A
AC 7.6 A
AC 9.5 A
OUTPUT
Output voltage
U
A
3 × 0 ... V
supply
Recommended motor power 100 % operation
Recommended motor power 125 % operation
P
Mot
P
Mot 125
1.1 kW / 1.5 HP
1.5 kW / 2.0 HP
1.5 kW / 2.0 HP
2.2 kW / 3.0 HP
2.2 kW / 3.0 HP
3.0 kW / 4.0 HP
Rated output current 100 % operation
Rated output current 125 % operation
I
N
I
N 125
AC 5.7 A
AC 7.1 A
AC 7.3 A
AC 9.1 A
AC 8.6 A
AC 10.8 A
Apparent output power 100 % operation
Apparent output power 125 % operation
S
N
S
N 125
2.3 kVA
2.9 kVA
3.0 kVA
3.7 kVA
3.5 kVA
4.3 kVA
Minimum permitted braking resistance value (4
quadrant operation)
R
BW_min
27
GENERAL INFORMATION
Power loss 100 % operation
Power loss 125 % operation
P
V
P
V 125
75 W
90 W
90 W
110 W
105 W
140 W
Current limitation
150 % I
N
for at least 60 seconds
Terminal cross section / tightening torque
Terminals
4 mm
2
/ AWG12 / 0.5 Nm / 4 lb in
Dimensions
W × H × D
80 × 273.5 × 163.5 mm / 3.1 × 10.77 × 6.437 in
Weight
m
2.2 kg / 4.9 lb
163.5 (6.437)
273.5 (10.77)
284.5 (1
1.20)
308.5 (12.15)
159.5 (6.280)
149 (5.87)
6 (0.2)
6 (0.2)
80 (3.1)
373.5 (14.70)
70 (2.8)
P
i
f
kVA
Hz
n
Summary of Contents for MOVITRAC MC07B0037-2A3-4-00