Unit status codes
Operation
10.3.2 LED flash codes
The LED on the front of the unit signals the following states:
10.4
Unit status codes
Use status word 1 to determine the unit status code.
Status
Display (optional with
FBG)
LED flash code status of basic
unit
"ENABLE"
Speed
Constant green light
"ENABLE" at current limit
Speed flashes
Rapid green flashing
"CURRENT AT STAND-
STILL"
dc
Slow green flashing
Timeout
Errors 43 / 46 / 47
Flashing green/yellow
"NO ENABLE"
Stop
Constant yellow light
"FACTORY SETTING"
SEt
Rapid yellow flashing
"CONTROL.INHIBIT"
oFF
Rapid yellow flashing
"24 V operation"
Flashing 24U
Slow yellow flashing
"SAFE STOP"
Flashing U
Slow yellow flashing
FGB manual operation
active or inverter stopped
using "stop" button.
FGB manual operation
symbol or "stop" is flashing
Yellow on long, off briefly
Copy
Fault 97
Flashing red/yellow
System error
Errors 10 / 17 ... 24 / 25 / 32
/ 37 / 38 / 45 / 77 / 80 / 94
Constant red light
Overvoltage / phase failure
Errors 4 / 6 / 7
Slow red flashing
Overload
Errors 1 / 3 / 11 / 44 / 84
Rapid red flashing
Monitoring
Errors 8 / 26 / 34 / 81 / 82
2 x red flashing
Motor protection
Errors 31 / 84
3 x red flashing
WARNING!
Incorrect interpretation of display U = "Safe stop" active.
Severe or fatal injuries.
The display U = "Safe stop" is not safety-related and must not be used as a safety
function.
Code
Meaning
0x0
Not ready
0x1
Controller inhibit
0x2
No enable
0x3
Standstill current active, no enable
0x4
Enable
0x8
Factory setting is active
0
0
I