18
System Manual V2 – MOVITRAC® B
4
General technical data
Technical Data
4.2
General technical data
The following technical data applies to all MOVITRAC
®
B frequency inverters indepen-
dent of size and power.
MOVITRAC
®
B
All sizes
Interference immunity
Complies with EN 61800-3
Interference emission with
EMC-compliant installation
According to limit value class
1)
•
Sizes 0 ... 2: C2 without further measures
•
Sizes 0 ... 5: C1 with corresponding filters / folding ferrites
C1/C2 to EN 61800-3
Leakage current
> 3.5 mA
Ambient temperature
ϑ
A
(up to 60 °C (140 °F) with cur-
rent reduction)
•
230 V, 0.25 ... 2.2 kW (0.34 ... 3.0 HP) / 400/500 V, 0.25 ... 4.0 kW (0.34 ... 5.4 HP)
With overload capacity
(max. 150% for 60 s):
I
D
= 100 % I
N
/ f
PWM
= 4 kHz: -10 °C ... +40 °C (14 °F ... 104 °F)
Without high overload capacity:
I
D
= 100 % I
N
/ f
PWM
= 4 kHz: -10 °C ... +50 °C (14 °F ... 122 °F)
I
D
= 100 % I
N
/ f
PWM
= 8 kHz: -10 °C ... +40 °C (14 °F ... 104 °F)
I
D
= 125 % I
N
/ f
PWM
= 4 kHz: -10 °C ... +40 °C (14 °F ... 104 °F)
•
3 × 230 V, 3.7 ... 30 kW (5.0 ... 40 HP) / 400/500 V, 5.5 ... 75 kW (7.4 ... 100 HP)
With overload capacity
(max. 150% for 60 s):
I
D
= 100 % I
N
/ f
PWM
= 4 kHz: 0 °C ... +40 °C (32 °F ... 104 °F)
Without overload capacity:
I
D
= 100 % I
N
/ f
PWM
= 4 kHz: 0 °C ... +50 °C (32 °F ... 122 °F)
I
D
= 100 % I
N
/ f
PWM
= 8 kHz: 0 °C ... +40 °C (32 °F ... 104 °F)
I
D
= 125 % I
N
/ f
PWM
= 4 kHz: 0 °C ... +40 °C (32 °F ... 104 °F)
•
Mounting plate with
"cold plate"
< 70°C (+158 °F)
Derating ambient temperature
(current reduction)
2.5 % I
N
per K at 40 °C ... 50 °C (104 °C ... 122 °F)
3 % I
N
per K at 50 °C ... 60 °C (122 °F ... 140 °F)
Climate class
EN 60721-3-3, class 3K3
Storage temperature
Transportation temperature
-25 °C ... +75 °C (–13 °F ... 167 °F)
-25 °C ... +75 °C (–13 °F ... 167 °F)
Cooling type
Self-cooling: 230 V
: ≤
0.75 kW (1.0 HP)
400/500 V
: ≤
1.1 kW (1.5 HP)
Forced cooling: 230 V
: ≥
1.1 kW (1.5 HP)
(temperature controlled fan, 400/500 V
: ≥
1.5 kW (3.0 HP)
Response threshold 45 °C (113 °F])
Degree of protection EN
60529 (NEMA1)
Sizes 0 ... 3: IP20
Sizes 4 ... 5 power connections:
•
IP00
•
With the supplied Plexiglas cover mounted and mounted shrinking tube (not sup-
plied) IP10
Operating mode
Continuous duty
Overvoltage category
III according to IEC 60664-1 (VDE 0110-1)
Mains voltage tolerance
EN 50160: ±10 %
Pollution class
2 according to IEC 60664-1 (VDE 0110-1)
P
i
f
kVA
Hz
n
Summary of Contents for MOVITRAC MC07B0037-2A3-4-00