System Manual V2 – MOVITRAC® B
191
9
Manual operation with FBG11B speed control module
Startup
9.6
Manual operation with FBG11B speed control module
FBG11B speed control module of the keypad
(local manual operation): LED
flashes
The only relevant parameters in "FBG speed control module" operating mode are:
•
P122 Direction of rotation FBG manual operation
•
"RUN" and "STOP/RESET" keys
•
Speed control module
When the FBG speed control module is activated, the symbol flashes.
You limit the smallest speed with
P301 Minimum speed
and the largest speed with the
n
max
symbol.
After a fault, a reset can be performed using the "STOP/RESET" button via the terminal
or the interface. After a reset, the "manual speed control module" operating mode will
be active once again. The drive remains stopped.
The
Stop
display flashes to indicate that you have to re-enable the drive by pressing
"RUN."
The parameter
P760 Locking RUN/STOP keys
does not have any effect in "manual
speed control module" operating mode.
Removing the FBG11B keypad will trigger a stop response.
0
0
I