Technical data of MOVITRAC® B
Technical Data
4.4.8
AC 400 / 500 V / 3-phase / size 4 / 37 ... 45 kW / 50 ... 60 HP
MOVITRAC
®
MC07B (3-phase supply system)
0370-503-4-00
0450-503-4-00
Part number
828 531 4
828 532 2
INPUT
Rated mains voltage
V
supply
3 × AC 380 ... 500 V
Rated mains frequency
f
supply
50 / 60 Hz ± 5%
Rated mains current, 100 % operation
Rated mains current, 125 % operation
I
supply
I
supply 125
AC 65.7 A
AC 81.9 A
AC 80.1 A
AC 100.1 A
OUTPUT
Output voltage
U
A
3 × 0 ... V
supply
Recommended motor power 100 % operation
Recommended motor power 125 % operation
P
Mot
P
Mot 125
37 kW / 50 HP
45 kW / 60 HP
45 kW / 60 HP
55 kW / 74 HP
Rated output current 100 % operation
Rated output current 125 % operation
I
N
I
N 125
AC 73 A
AC 91.3 A
AC 89 A
AC 111.3 A
Apparent output power 100 % operation
Apparent output power 125 % operation
S
N
S
N 125
50.6 kVA
63.2 kVA
61.7 kVA
77.1 kVA
Minimum permitted braking resistance value (4
quadrant operation)
R
BW_min
6
GENERAL INFORMATION
Power loss 100 % operation
Power loss 125 % operation
P
V
P
V 125
1200 W
1450 W
1400 W
1820 W
Current limitation
150 % I
N
for at least 60 seconds
Terminal cross section / tightening torque
Terminals
25 mm
2
/ AWG4
35 mm
2
/ AWG2
14 Nm / 120 lb in
Dimensions
W × H × D
280 × 522 × 250 mm / 11.0 × 20.6 × 9.84 in
Weight
m
27 kg / 60 lb
280 (11.0)
140 (5.51)
499 (19.6)
7 (0.3)
522 (20.6)
250 (9.84)
246 (9.69)
P
i
f
kVA
Hz
n