148
System Manual V2 – MOVITRAC® B
6
Application examples
Project Planning
6.20.3 Speed-controlled agitator
In this application, you can control the speed using the FBG speed control module.
The keypad is used to control:
•
Reset
•
Start
•
Stop
•
Speed control.
Select the "FGB speed control module" icon to operate the agitator.
Parameters
Adapt the following parameters for the agitator:
•
P122 FBG manual operation: Direction of rotation
•
Ramp t11 up (adjust with keypad or parameter P130)
•
Ramp t11 up (adjust via keypad icon or parameter P131)
•
P301 Minimum speed
•
P302 Maximum speed
•
P860 PWM frequency
RUN
STOP
RESET