System Manual V2 – MOVITRAC® B
79
4
Fieldbus connection
Technical Data
4.25.5 Fieldbus interface DFE32B for PROFINET IO RT
Description
The MOVITRAC
®
B frequency inverter enables you to use the DFE32B option to
connect to higher-level automation systems via PROFINET IO RT thanks to its powerful,
universal fieldbus interface.
Refer to the publication "DFE32B PROFINET IO Fieldbus Interface" for installation.
Electronics data
DFE32B option
External voltage
supply via X26
U = DC 24 V (–15 %, +20 %)
I
max
= DC 200 mA
P
max
= 3.4 W
Application
protocols
•
PROFINET IO
(Ethernet frames with frame identification
8892
hex
) to control and set parameters for the inverter.
•
HTTP
(Hypertext Transfer Protocol) for diagnostics using a
Web browser.
•
SMLP
(Simple Movilink Protocol), protocol used by
MOVITOOLS
®
MotionStudio.
Port numbers
used
•
300 (SMLP)
•
80 (HTTP)
Ethernet services
•
ARP
•
ICMP (Ping)
OSI Layer 1/2
Ethernet II
Baud rate
100 Mbaud in full duplex process
Connection
technology
2 x RJ45 with internal switch and auto crossing
Addressing
4 byte IP address or MAC-ID (00:0F:69:xx:xx:xx)
Manufacturer ID
(vendor ID)
010A
hex
GSD file name
GSML-V2.1-SEW-DFE-DFS-2Ports-YYYYMMTT.xml
P
i
f
kVA
Hz
n
Summary of Contents for MOVITRAC MC07B0037-2A3-4-00
Page 250: ......