32
V115E_09.20
T r o u b l e s h o o t i n g
Series-65H Hoist Pos 4
68 • vacon
Fault Tracing
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
8
8
8
8
22
23
EEPROM
checksum fault
-
parameter save fault
-
faulty operation
-
component failure
24
Changed data
warning
Changes may have occurred in the different counter data due to mains interrup-
tion
25
Microprocessor
watchdog fault
-
faulty operation
-
component failure
29
Thermistor fault
Thermistor is broken.
37
Device change
Option board changed.
Different power rating of drive.
38
Device added
Option board added.
Drive of different power rating added.
39
Device removed
Option board removed.
Drive removed.
40
Device unknown
Unknown option board or drive.
41
IGBT temperature
43
Encoder fault
Note the exceptional Fault data record. See Param. 7.3.4.3. Additional codes:
1 = Encoder 1 channel A is missing, wrong connection or broken cable
2 = Encoder 1 channel B is missing, wrong connection or broken cable
3 = Both Encoder 1 channels are missing, wrong connection or broken cable
4 = Encoder reversed, channels swapped
50
Analogue input I
in
< 4mA (selected
signal range 4 to
20 mA)
Current at the analogue input is < 4mA.
-
control cable is broken or loose
-
signal source has failed
51
External fault
Digital input fault.
52
Keypad communi-
cation fault
The connection between the control keypad and the frequency converter is
broken.
53
Fieldbus
communication
fault
The connection from the fieldbus to the frequency converter is broken.
54
SPI communi-
cation fault
The connection between the component board and the control board is broken.
55
External brake
control
Fault is activated by the mechanical brake control logic. Check parameters and
external brake device. See
parameter 2.8.4.1
56
Shaft speed
Fault is activated if calculated speed is different compared to actual speed.
See
parameter 2.8.4.2
.
57
Torque
supervision
Actual torque above torque limits. See
parameter 2.8.4.6
58
Minimum current
Motor current is less than set limit
parameter 2.8.4.8
59
Direction request
Digital inputs DIN1 and DIN2 are ON at the same time. See
parameter 2.8.4.7.
60
Evacuation
Fault is generated during the evacuation process.
61
Zero speed time
Zero current measured later than 2 seconds from start command.
See
parameter 2.8.4.9.
62
Evacuation
Voltage
Evacuation active and voltage has exceeded the limit value.
Evacuation supply voltage 230VAC
±
10%
63
Identification
Motor is not connected to the frequency converter. Wrong motor data is given.
Table 20. Fault codes
Summary of Contents for 65H Series
Page 2: ...2 T a b l e o f C o n t e n t s Series 65H Hoist Pos 0 V115E_09 20...
Page 10: ...G e n e r a l i n f o r m a t i o n 2 V115E_09 20 Series 65H Hoist Pos 1...
Page 26: ...G e n e r a l i n f o r m a t i o n 18 V115E_09 20 Series 65H Hoist Pos 1 4450 L L1 L2 TWIN...
Page 34: ...G e n e r a l i n f o r m a t i o n 26 V115E_09 20 Series 65H Hoist Pos 1...
Page 36: ...S a f e t y i n s t r u c t i o n s 2 V115E_09 20 Series 65H Hoist Pos 2...
Page 46: ...S a f e t y i n s t r u c t i o n s 12 V115E_09 20 Series 65H Hoist Pos 2 MAX 1000 kg TH_10E...
Page 54: ...S a f e t y i n s t r u c t i o n s 20 V115E_09 20 Series 65H Hoist Pos 2 Tx527...
Page 55: ...21 S a f e t y i n s t r u c t i o n s V115E_09 20 Series 65H Hoist Pos 2...
Page 82: ...O p e r a t i n g i n s t r u c t i o n s 24 V115E_09 20 Series 65H Hoist Pos 3...
Page 84: ...2 V115E_09 20 T r o u b l e s h o o t i n g Series 65H Hoist Pos 4...
Page 124: ...10 V115E_09 20 Service and maintenance Series 65H Hoist Pos 5...
Page 144: ...30 V115E_09 20 Service and maintenance Series 65H Hoist Pos 5 Picture 3c Picture 3b...
Page 154: ...40 V115E_09 20 Service and maintenance Series 65H Hoist Pos 5...
Page 156: ...Inspection forms V115E_09 20 Series 65H Hoist Pos 8 SC HOIST INSPECTION FORMS...