ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL
144
FRONT FORK DAMPER TUBES COMPARISON
GT Continental 535
INTERCEPTOR 650 &
CONT. GT. 650
Compression Damping
Less bleed through the
damper tube to provide
more control when
coupled with the 10 slot
base valve
Rebound Damping
Compression Damping
Rebound Damping
REAR SUSPENSION UNITS (RSU) COMPARISON
GT Continental 535
INTERCEPTOR 650 &
CONT. GT. 650
Small cantilever
upper RSU mount-
ing method
In consistent 2-10
Bar Gas pressure
Inverted Piggy
back reservoir
Infinite preload
adjustment
Dia 14mm Upper RSU mount
solidly incorporated into
frame. Fixing method does
not take any vertical load
and only secures any lateral
movement.
New RSU (Gabriel)
6 to 10 Bar Gas pressure
is maintained to give
consistent damping.
Stepped Preload feature
to ensure correct preload
settings
Progressive rate tapered
bump stop to ensure
smooth progression
through RSU stroke.
Summary of Contents for CONTINENTAL GT 650 TWIN 2018
Page 1: ...650 TWIN SERVICE TRAINING MANUAL ...
Page 190: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 189 WIRING HARNESS ABS MODULATOR DOL Connector ...
Page 193: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 192 WIRING HARNESS SIGNALLING SYSTEM ...
Page 194: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 193 WIRING HARNESS ES STARTING SYSTEM ...
Page 195: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 194 WIRING HARNESS EFI SYSTEM IGNITION ...
Page 196: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 195 NOTES ...
Page 197: ...ROYAL ENFIELD 650 TWIN SERVICE TRAINING MANUAL 196 NOTES ...
Page 198: ......