R&S ZVH
Cable and Antenna Test Mode
Analyzing Measurement Results
Operating Manual 1309.6946.12 - 09
65
2.3.2.4 Automatic Positioning of Markers
The R&S ZVH offers functions that make setting the markers easier or allow to make
instrument settings on the basis of the current marker position:
● "Set to Peak"
The Peak function places the active marker or the delta marker on the highest level
value of the trace.
● "Set to Next Peak"
The Next Peak function places the active marker or delta marker on the next
highest level value of the trace, relative to its current position.
● "Set to Minimum"
The Minimum function places the active marker or delta marker on the lowest
value of the trace.
► Press the MKR
key.
► Press the "Set to Peak", "Set to Next Peak" or "Set to Minimum" softkey.
The R&S ZVH positions the marker accordingly.
Sorting markers
A special marker function available for distance-to-fault measurements is that you can
sort them in ascending order.
► Press the MKR
key.
► Press the "Sort Markers" softkey.
The R&S ZVH sorts the markers in ascending order with marker 1 being positioned on
the lowest distance. The marker values remain the same.