2.3 Analyzing Measurement Results
2.3.1 Working with Traces
2.3.1.1 Selecting the Trace Mode
The R&S ZVH provides several trace modes. The trace mode defines the way the
R&S ZVH writes the trace.
For information on the trace modes see "
► Press the TRACE key.
► Press the "Trace Mode" softkey.
► Select the "Clear/Write" or "Average:" menu item.
2.3.1.2 Suppressing Interfering Signals
When performing measurements in the field, you may encounter interfering signals
from surrounding signal sources like other antennas. These signals could distort the
actual measurement and therefore lead to false assumptions about faults in the system
you are measuring.
The R&S ZVH provides a method to suppress signals resulting from interfering sources
without affecting the accuracy of the actual measurement.
► Press the TRACE key.
► Press the "Trace Mode" softkey.
► Select the "Suppression On" menu item to activate suppression of interference.
The R&S ZVH looks for signals that interfere with the measurement and
suppresses them in the result display. Faults in the system you are measuring are,
however, still displayed correctly.
The R&S ZVH automatically determines the aperture for the suppression. If you want
to apply a particular aperture, you can also set it manually.
► Press the TRACE key.
► Press the "Trace Mode" softkey.
► Select the "Aperture Manual" menu item.
The R&S ZVH turns automatic aperture calculation off. The default aperture is 1.
► Press the "Trace Mode" softkey.
► Select the "Aperture Size: 1" menu item.