6.4.2.1 Performing Transmission Measurements
Calibrate the measurement for transmission measurements.
► Press the CAL key.
► Press the "Full 2-Port" softkey.
► Perform calibration. For more
information see "
".
► Reconnect the DUT.
The R&S ZVH shows the
characteristics of the DUT
(magnitude and phase) as
numerical values.
6.4.2.2 Performing Reflection Measurements
Calibrate the measurement for reflection measurements.
► Press the CAL key.
► Press the "Full 1-Port" softkey (for calibration on port 1).
► Perform calibration. For more information see "
".
► Reconnect the DUT.
The R&S ZVH shows the characteristics of the DUT (magnitude and phase) as
numerical values.
Note that for calibration to remain valid, frequency parameters, bandwidth and