T
echnical
B
ulletin
PAGE: 1/2
Model: Leo-C2/P2
Date:
5-Mar-18
No.:
RD0A5002
Subject:
Troubleshooting procedure for 50 mm pitch banding
Prepared by:
S. Katoh
From: Sales Strategy Section, 1st CP Business Dep.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier 2
Tier 0.5
SYMPTOM
Banding in approximately 50mm pitch appears on the printouts, which is noticeable
especially in light halftone images.
CAUSE
Bug in the DEMS/DSC software
SOLUTION
Temporary Solution:
Do the procedure on the following page until the permanent solution becomes available.
Permanent Solution:
Modified software is scheduled for release in late April 2018.