T
echnical
B
ulletin
PAGE: 1/1
Model:
Leo-C2/P2
Date:
Apr-24-18
No.:
RD0A5014
Subject:
Caution when installing the operation panel
Prepared by:
H Kawamura
From:
PPCS Section, CIP Product Quality Management Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier 2
Tier 0.5
SYMPTOM
The blue LED on the Attention Light does not turn on.
CAUSE
The rear cover contacts and breaks the resistor (boxed in red below) when the operation
panel is installed.
SOLUTION
The cover will be modified so that it does not come in contact with the resistor.
Applied: TBD
In the field:
Slide the rear cover upward and secure the screw when attaching the cover to the
operation panel.