T
echnical
B
ulletin
PAGE: 1/1
Model:
Leo-C2/P2
Date:
13-Jun-18
No.:
RD0A5020
Subject:
Part Replacemnt Alert Display Correction
Prepared by:
H Kawamura
From:
PPCS Section, CIP Product Quality Management Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier 2
Tier 0.5
SYMPTOM
The wrong alert for PM part replacemnt is displayed.
CAUSE
The wrong SP was activated/set at the factory.
SOLUTION
Do the following at installation or next service visit:
1. Set
SP5-062-113
(Part Replacement Alert Display: Fuser Belt Smoothing Roller) to a
value of
“0”.
Note:
This will deactivate the alert.
2. Set
SP5-062-114
(Part Replacement Alert Display: Fuser Cleaning Unit) to a value of
“1”.
Note:
This will activate the alert.
Cut in Serial Numbers
TBD (RTB to be revised)