SYMPTOM
SC514 occurs.
CAUSE
The harness inside the right drawer is damaged by the rotary gate, causing the two parts
to contact one another.
SOLUTION
During the next visit, check whether the harness is contacting the rotary gate.
Subject:
Prevent harness damage from contacting the rotary gate
Prepared by:
H Kawamura
From:
PPCS Section, CIP Product Quality Management Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier 2
Tier 0.5
Rotary gate
Damaged harness