T
echnical
B
ulletin
PAGE: 40/51
Reissued: 1-Mar-19
Model:
Leo-C2/P2
Date:
27-Dec-18
No.:
RD0A5038b
SC568-00 SC593-01 SC665-05 SC688-03 (Ref. RTB RD0A5030)
SYMPTOM
At the 5V ground fault, the following SC occurs
SC593-01
SC688-03
SC568-00
SC665-05
CAUSE
The harness in the PTB unit contacts the shaft.
ACTION
Reroute the harness to prevent the harness from contacting the shaft
<Procedures>
1. Remove the PTR unit (refer to service manual 4. Replacement and Adjustment > PTB
Unit).
2. Remove the paper transport belts (refer to service manual 4. Replacement and
Adjustment > Paper Transport Belts).
3. The harness must be rerouted in the following 5 locations.