T
echnical
B
ulletin
PAGE: 13/16
Reissued: 17-Jul-18
Model:
Leo-C2/P2
Date:
20-Mar-18
No.:
RD0A5005a
D-3. Adjust PRT AC Bias in steps of 2. Check the results at each step.
Stop when results are acceptable. If satisfactory results are not obtained even
after increasing or decreasing the value to “+10” or “-10”, apply the value that
produced the best results and continue the procedure.
PTR
AC
Bias 1218-XX
-2
-4
-6
-8
-10
+2
+4
+6
+8
+10
D-4. Set the paper transfer current (belt-to-paper PTR DC bias) in the Advanced Settings
below according to the print mode; simplex or duplex, BW or FC or FCS or S, as
follows:
1) First, set the value to “-2” and check the print quality. If acceptable, stop the
procedure. If unacceptable, continue.
2) Set the value to “-5” and check the print quality. Stop or continue depending on
the results.
Advanced Settings
#1214-XX: Paper Transfer Output
#1214-
01
BW_Side 1
#1214-
02
BW_Side2
#1214-
03
FC_Side 1
#1214-
04
FC_Side 2
#1214-
05
FCS_Side 1
#1214-
06
FCS_Side 2
#1214-
07
S_Side 1: Clear/Special
#1214-
08
S_Side 1: White
#1214-
11
S_Side 2: Clear/Special
#1214-
12
S_Side 2: White
PTR
DC
Bias
1214-XX
-2
-5
+2
+5
Summary of Contents for Leo-C2/P2
Page 213: ...Technical Bulletin PAGE 3 4 Reissued 18 Oct 18 Model Leo C2 P2 Date 14 Sep 18 No RD0A5034a...
Page 241: ...Technical Bulletin PAGE 6 51 Reissued 1 Mar 19 Model Leo C2 P2 Date 27 Dec 18 No RD0A5038b...
Page 268: ...Technical Bulletin PAGE 33 51 Reissued 1 Mar 19 Model Leo C2 P2 Date 27 Dec 18 No RD0A5038b SC...