T
echnical
B
ulletin
PAGE: 2/20
Reissued: 16-Nov-18
Model:
Leo-C2/P2
Date:
6-Mar-18
No.:
RD0A5004b
Auto Adjust Image Position
(Auto Registration Adjustment)
Prints out test charts printed of ‘registration marks’ at the four corners of the pages. The TIM-Mag
Unit scans these marks for the system to automatically adjust the registration.
Go to:
Tray Paper settings
Select Tray
Select Media setting and Edit the Settings
Auto Adjust Image Position
NOTE
: The media must be associated to the tray.
Test chart and Check sheet
1. Front Side Registration: Test chart x10, Check sheet x1
2. Front & Back Registration
:
Test chart x30, Check sheet x1
NOTE:
Number of test charts can be specified in Adjustment Settings for Skilled
Operators #0107. Number of check sheets can be specified in Advanced
Settings #1102.
Results of the adjustment made by Auto Adjust Image Position are stored in
Advanced Settings #1101 [01-18]. The system refers to these parameters when
printing.
Fine-tuning is made by adjusting the parameters in Advanced Settings #1104 [01-
12]. Press
Manual Adjustment Image Position
to jump to #1104.