11.13 Fishfinder alarms
The display can be configured to provide a number of fishfinder
alarms.
The following fishfinder alarms can be set when a DSM is detected,
or when the simulator is on:
•
Fish
— alarm sounds when a target meets the specified sensitivity
level and, is within the depth limits (if enabled). The greater the
fish alarm sensitivity, the greater the number of target image
depths displayed.
•
Fishfinder Deep
— alarm sounds when the DSM detects that the
depth is greater than the deep limit.
•
Fishfinder Shallow
— alarm sounds when the DSM detects that
the depth is less than the shallow limit.
Setting up fish alarms
The fish alarms are configured from the alarms menu.
From the homescreen:
1. Select
Set-up
.
2. Select
Fish
.
The Fish alarms menu is displayed.
3. Select
Fish
so that On is highlighted.
4. Select
Fish Sensitivity
.
5. Use the
Rotary Control
to adjust the fish sensitivity to the
required setting.
The greater the fish alarm sensitivity, the greater the number of
target image depths displayed.
6. Select
Fish Depth Limits
so that
On
is highlighted.
The shallow and deep fish limit settings will be activated in the
menu.
7. Select
Shallow Fish Limit
.
8. Use the
Rotary Control
to adjust the shallow fish limit to the
required setting.
9. Select
Deep Fish Limit
.
10. Use the
Rotary Control
to adjust the deep fish limit to the
required setting.
Setting up fishfinder deep alarm
From the homescreen:
1. Select
Set-up
.
2. Select
Alarms
.
3. Select
Fishfinder Deep
.
4. Select Deep so that On is highlighted.
Selecting Deep will switch between On and Off.
5. Select
Deep Limit
.
6. Use the
Rotary Control
to adjust the setting to the required
value.
7. Press the
Ok
button to confirm value.
Note:
The Deep Limit cannot be set to less than the Shallow
Limit.
Setting up fishfinder shallow alarm
From the homescreen:
1. Select
Set-up
.
2. Select
Alarms
.
3. Select
Fishfinder Shallow
.
4. Select Shallow so that On is highlighted.
Selecting Shallow will switch between On and Off.
5. Select
Shallow Limit
.
6. Use the
Rotary Control
to adjust the setting to the required
value.
7. Press the
Ok
button to confirm value.
210
e7 / e7D — User reference
Summary of Contents for e7
Page 2: ......
Page 4: ......
Page 14: ...14 e7 e7D User reference ...
Page 18: ...18 e7 e7D User reference ...
Page 62: ...62 e7 e7D User reference ...
Page 124: ...124 e7 e7D User reference ...
Page 132: ...132 e7 e7D User reference ...
Page 174: ...174 e7 e7D User reference ...
Page 211: ...Note The Shallow Limit cannot be set to greater than the Deep Limit Using the fishfinder 211 ...
Page 248: ...248 e7 e7D User reference ...
Page 260: ...260 e7 e7D User reference ...
Page 272: ...272 e7 e7D User reference ...
Page 278: ...278 e7 e7D User reference ...
Page 316: ...316 e7 e7D User reference ...
Page 317: ...Owner notes ...
Page 318: ...Owner notes ...
Page 319: ......
Page 320: ...www raymarine com ...