Chapter 4: Front Panel Display and Controls
41
Press the
ESC
button on the front panel at any time to return to Normal
Display.
Test User UST1
This function checks whether user stations (USTs) are functioning
properly.
1. Press
the or button to change user port number. Display will read
"OK", "None", or "Failed."
If a "Failed" condition is detected, make sure the Cat5 UTP cable is
installed properly and secured, or try using another user station
(UST) to see if the user station under test has become defective.
2. Press
the
ESC
button on the front panel at any time to return to Normal
Display.
Test Chan. UKVM
This function checks whether a CIM is functioning properly.
1. Press
the or button to change channel number. Display will read
"OK", "None", or "Failed."
If a "Failed" condition is detected, make sure the Cat5 UTP cable is
installed properly and secured, or try using another CIM to see if
the CIM under test has become defective.
2. Press
the
ESC
button on the front panel at any time to return to Normal
Display.
Stacking Support
1. Press
the or button to set the Stacking Unit ID number (0~3 for a
P2-UMT832M or 0~1 for a P2-UMT1664M).
The default is set to "0" (no Stacking Units connected).
If you wish to add Stacking Units, this number must be equal to the
number of Stacking Units connected.