Chapter 3: Rackmount and Installation
22
P2ZCIM and Z-CIM (local single-user IBM PS/2 compatible
servers):
Please see
Paragon II and P2ZCIMs
(see "P2ZCIMs and Z-CIMs"
on page 126) for installation instructions.
b. Plug in and turn on the server. If the CIM is installed and operating
properly, the CIM’s green LED will start blinking: once per second
while the CIM is idle, more quickly while data is transmitted in
either direction.
c. Connect one end of a Cat5 UTP cable to channel port #1 on the
back of the Paragon switch. Connect the other end of the cable to
the RJ45 port on the CIM.
6. Configure the CIM and the attached server.
a. The monitor attached to the user station will display the Selection
Menu; with the server you just connected displayed in green. Use
the and keys to move the highlight to that entry and press
Enter. If you can access and operate the server normally, the CIM
is connected successfully. Raritan recommends you give the
server a meaningful system name at this time, as described in the
next steps.
Note: If your video image is fuzzy, you can adjust the video gain to
focus the video image. Fuzzy video images may happen if you are
using an LCD flat-panel monitor. For more information, see
Video
Gain Adjustment
(on page 60). The P2-EUST and P2 EUST/C
provide automatic and manual skew compensation, which also help
improve the video quality. For more information, see
Skew
Compensation with P2-EUST or P2-EUST/C
(on page 61).
b. Press
F5
to activate the Administration Menu. Use the and
keys to move the highlight to the Channel Configuration entry and
press Enter.