B-1715(3)
INSTRUCTION SHEET - HS5L Series
Solenoid Type Safety Switch
( 1 / 8 )
2016.04
2
Specifications and Ratings
*2 Ratings approved by safety agencies
(1)TÜV/CCC rating AC-15 250V/0.75A
DC-13 30V/2.3A
(2)UL , c-UL rating AC-15 250V/0.75A : Pilot Duty
DC-13 30V/1A : Pilot Duty
The M20 threaded opening must be filled by a Listed or
Recognized Component Liquid-Tight Flexible Cord Fitting
in order to maintain the Tye 4X Indoor use only rating.
(3)KOSHA rating
AC-15 250V/0.75A
DC-13 30V/1A
*3 Basic insulation of 2.5kV impuise withstand circuits and between contact circuit
SELV(safety extra low voltage) or circuits (such as 230V AC circuits) at the same
time, the SELV or PELV arequirements are met any more.
*4 The actuator locking strength is rated at 1400N of static load. Do not apply a load
higher than the rated value. When a higher load is expected to work on the
actuator, provide an additional system consisting of another safety switch without
lock (such as the HS5D safety switch) or a sensor to detect door opening and stop
the machine.
*5 F1max is maximum force. The actuator’s guard-locking force Fzh is calculated in
accodance with GS-ET-19:
*6 Make sure that a fast acting fuse for short-circuit protection trips before
overhea ing of he wires.
1
Type
HS5L-VD44LM-G
Solenoid Voltage / Lock Mechanism
4 : 24V DC / Spring Lock
7Y : 24V DC / Solenoid Lock
Pilot Light Rated Voltage
4 : 24V DC
Indicator Color
G : Green
Circuit Code
Rear Unlock Button
Blank : Wi hout Rear Unlock Button
L : Rear Unlock Button
Standard type
Contact Congifiguration
*1 Only type No. on √ mark are supplied as standard.
Contact IDEC for the other if required.
Spring Lock Type Solenoid Lock Type
Main
circuit
-
-
-
-
-
-
-
-
-
-
-
1NC+1NC
1NC+1NC
-
-
1NC+1NC
1NC+1NC
1NC+1NC
1NC+1NC
1NC+1NC
1NC+1NC
1NC+1NC
-
-
-
-
-
-
-
HS5L-
□
7Y4M-G
√
√
√
√
√
√
√
√
√
√
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HS5L-
□
44LM-G
-
-
-
√
√
√
√
√
-
-
-
√
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HS5L-
□
44M-G
√
-
-
√
√
√
√
√
√
√
√
√
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Door monitor
circuit
1NC
2NC
1NC,1NO
-
1NC,1NO
1NC,1NO
2NC
2NC
3NC
2NC,1NO
1NC
-
1NO
-
1NO
1NO
1NC
1NC
2NC
1NC,1NO
-
1NO
1NO
1NC
1NC
2NC
1NC,1NO
-
Lock monitor
circuit
1NC
-
-
2NC
1NC,1NO
2NC
1NC,1NO
2NC
1NC
1NC
2NC,1NO
-
1NC
1NC,1NO
1NO
1NC
1NO
1NC
-
-
1NC,1NO
1NC,1NO
2NC
1NC,1NO
2NC
1NC
1NC
2NC,1NO
XD
XF
XG
XH
VA
VB
VC
VD
VF
VG
VJ
DD
XB
XJ
A
B
C
D
F
G
J
TA
TB
TC
TD
TF
TG
TJ
Rear Unlock Button
CAUTION
Solenoid lock type
• This safety switch is designed to lock the actuator while the solenoid is energized
and to release it when deenergized.
• When the power to the solenoid is interrupted by accident, such as disconnection,
the lock is released before a machine stops ompletely. Then, the worker may be
exposed to hazards.
• This safety switch can be used only for limited applications which do not especially
need to be locked for safety.
Fzh
=
maximum force (F1max)
Safety coefficient (=1 3)
Applicable Standards
Applicable Directives
Thermal Current ‹th›
Contact Ratings
(Reference Values)
‹Ue, Ie›*2
Rated Operating Voltage
Rated Current
Turn ON Voltage
Turn OFF Voltage
Rated Power Consumption
Rated Operating Voltage
Rated Current
Light Source
llumination Color
Standards for Use
Solenoid
Indicator
Operating Condition
Inpulse withstand voltage
‹Uimp›
Raed Insulation voltage‹Ui›
Interlocking device Type
/ the level of coded
Device
Short-circuit Protective
current
Conditional short circuit
Degree of Protection
Contact Resistance
Direct Opening Force
Direct Opening Travel
when Locked
Actuator Tensile Strength
Electrical Durability
Mechanical durability
B10d
Operating Speed
Operating Frequency
Class of Protection
DC24V 100% duty cycle
200 mA (initial value)
Rated voltage x 85% maximum (at 20°C)
Rated voltage x 10% minimum (at 20°C)
Approx. 5W
DC24V 100% duty cycle
10 mA
LED
Green
Type 2 Interlocking device
/ low level coded actuator (EN ISO / ISO14119)
EN ISO / ISO14119, IEC60947-5-1, EN60947-5-1,
GS-ET-19,UL508, CSA C22 2 No.14, GB 14048. 5
IEC60204-1/EN60204-1
Low Voltage Directive, Machinery Directive
2.5A
AC Resistive load (AC12)
Inductive load (AC15)
DC Resistive load (DC12)
Inductive load (DC13)
30V
125V 250V
-
2.5A 1.5A
-
1.5A 0.75A
2.5A
1.1A
0.55A
2.3A
0.55A 0.27A
Class
II
(IEC61140) *3
900 operations/hour
0.05 to 1.0 m/s
2,000,000 (ISO 13849-1 Annex C Table C.1)
2,000,000 operations minimum (GS-ET-19)
The Rear Unlock Button: 3000 operations
minimum (Type HS5L-
□
L)
100,000 operations min. (AC-12 250V/1.5A)
2,000,000 operations min. (AC/DC 24V 100mA)
(900 operations / hour)
Fzh=1,400N minimum
F1max=1820N minimum (GS-ET-19) *4, *5
(Fzh=500N minimum: HS9Z-A55 actuator)
11 mm minimum (actuator: HS9Z-A51,A5P)
12 mm minimum (for other actuators)
120N minimum
50 m
Ω maximum (initial value)
IP67 (IEC60529) , Type 4X Indoor Use Only
50A(250V)
Use 250V / 10A fast acting type fuse *6
Operating Temperature
Operating Humidity
Pollution Degree
Altitude
2.5kV (Between ground and LED, solenoid circuit : 0.5kV)
250V (Between ground and LED, solenoid circuit : 30V)
-25 to +55°C (no freezing)
20 to 95%RH (no condensation)
3 (Inside 2)
2000m maximum
Thank you for purchasing this IDEC product. Confirm that the delivered product is
what you have ordered. Read this instruction sheet to make sure of correct operation.
In this operation instruction sheet, safety precautions are categorized in order of
importance to Warning and Caution :
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
Caution notices are used where inattention might cause personal injury or damage to
equipment.
INSTRUCTION SHEET
Original Instructions
Solenoid Type Safety Switch
HS5L Series
S A F E T Y P R E C A U T I O N S
CAUTION
WARNING
*In order to verify if the
product you are interested in
is certified with the S mark,
please check the following
section on our website: "List
of type numbers certified
with the S mark"
*
Shock Resistance
Vibration Resistance
Operating Extremes: 100m/s
2
, Damage Limits: 1000m/s
2
Operating Extremes:10 to 55 Hz, half amplitude 0.35mm
Damage Limits: 30 Hz, half amplitude 1.5mm
Conduit Cover
M : Standard type (M20)
SM : Cable side-routed type (M20)