Remote Control
R&S
®
FSPN
385
User Manual 1179.4363.02 ─ 01
Prerequisites for this command
●
Select Spot Noise vs Tune measurement (
CONFigure:SNTune:MEASurement[:
●
Turn on trace smoothing (
This command smoothes all traces. If you need to smooth each trace separately (pos-
sible in all measurements except Spot Noise vs Tune), use
.
Parameters:
<Value>
<numeric value>
Range:
1 to 20
*RST:
1
Default unit: PCT
Example:
//Smooth the traces by a magnitude of 10
%
SMO ON
SMO:APER 10
Manual operation:
See
[SENSe:]SMOothing[:STATe]
<State>
This command turns trace smoothing for a specific trace on and off.
When you turn on trace smoothing, you can define the smoothing magnitude
with
Prerequisites for this command
●
Select Spot Noise vs Tune measurement (
CONFigure:SNTune:MEASurement[:
This command smoothes all traces. If you need to smooth each trace separately (pos-
sible in all measurements except Spot Noise vs Tune), use
.
Parameters:
<State>
ON | OFF | 1 | 0
Example:
//Smooth the traces by a magnitude of 10
%
SMO ON
SMO:APER 10
Manual operation:
See
[SENSe:]SPURs:SUPPress
<State>
This command turns spur removal for all traces and windows on and off.
Parameters:
<State>
ON | OFF | 1 | 0
Common Measurement Settings