Common Analysis and Display Functions
R&S
®
FSPN
178
User Manual 1179.4363.02 ─ 01
7.5.2.1
Limit Line Management
Access
: "Overview" > "Analysis" > "Lines" > "Limit Lines"
For the limit line overview, the R&S
FSPN searches for all stored limit lines with the file
extension
.LIN
in the
limits
subfolder of the main installation folder. The overview
allows you to determine which limit lines are available and can be used for the current
measurement.
For details on settings for individual lines see
Chapter 7.5.2.2, "Limit Line Details"
For more basic information on limit lines see
Chapter 7.5.1, "Basics on Limit Lines"
................................................................................................ 179
Included Lines in Overview ( View Filter )
................................................................... 179
Name
The name of the stored limit line.
Unit
The unit in which the y-values of the data points of the limit line are defined.
Compatibility
Indicates whether the limit line definition is compatible with the current measurement
settings.
For more information on which conditions a limit line must fulfill to be compatible, see
Visibility
Displays or hides the limit line in the diagram. Up to 8 limit lines can be visible at the
same time. Inactive limit lines can also be displayed in the diagram.
Remote command:
CALCulate<n>:LIMit<li>:LOWer:STATe
CALCulate<n>:LIMit<li>:UPPer:STATe
CALCulate<n>:LIMit<li>:ACTive?
Limit Lines