Remote Control
R&S
®
FSPN
416
User Manual 1179.4363.02 ─ 01
Suffix:
<n>
.
1..n
<t>
1..n
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Turn on persistence for trace 2
DISP:TRAC2:PERS ON
Manual operation:
See
DISPlay[:WINDow<n>]:TRACe<t>:RESult[:TYPE]
<Resulttype>
This command selects the type of noise represented by the trace.
Suffix:
<n>
.
1..n
<t>
1..n
Parameters:
<Resulttype>
PN
Phase noise results.
AM
AM noise results.
PNAM
Sum of phase noise and AM noise.
Example:
//Show AM noise characteristics on trace 2
DISP:TRAC2:RES AM
Manual operation:
See
"Selecting the displayed result"
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>[:STATe]
<State>
This command turns a trace on and off.
The measurement continues in the background.
Suffix:
<n>
.
<w>
subwindow
Not supported by all applications
<t>
Example:
DISP:TRAC3 ON
Common Analysis and Display Functions