![background image](http://html1.mh-extra.com/html/radwag/uya-4y/uya-4y_user-manual_3937880145.webp)
- 145 -
32.2. PRINTER
<Printer> submenu enables:
•
Setting communication port with a printer.
•
Defining printer’s code page (default 1250).
•
Defining controlling codes for PCL printer or EPSON label printer.
Caution: CODES MUST BE ENTERED IN A HEXADECIMAL FORM!
•
Defining printout standards.
Speed of transmission respective for a printer (See: Printer settings) must be chosen for the balance
to ensure its right cooperation with a printer (diacritical signs specified for a given language).
Additionally, printout and printer code pages must be identical.
Code page accordance may be obtained as follows:
•
by setting the right code page in the printer (see the printer manual) – respective to printout
code page set in a balance; or
•
by sending control code from a balance to the printer, which automatically sets the right code
page (respective to code page set in a balance) in advance before execution of the data
printout – it is possible only for printers supplied with such option.
Exemplary balance settings for a correct cooperation (Polish diacritical signs printout) with EPSON
printer connected to RS232 port:
1.
EPSON TM-U220B Dot matrix printer
Communication parameters:
•
baud rate
– 9600 bit/s
•
data bits
– 8
•
stop bits
– 1
•
parity
– none
Printer’s parameters:
•
port
– COM1 or COM2 (the one to which the printer is connected)
•
code page
– 852
•
controlling codes
– 1B7412
2.
Thermal printer EPSON TM-T20
Communication parameters:
•
baud rate
– 38400 bit/s
•
data bits
– 8
•
stop bits
– 1
•
parity
– none
Printer’s parameters:
•
port
– COM1 or COM2 (the one to which the printer is connected)
•
code page
– 1250
•
controlling codes
– 1B742D
or
Printer’s parameters:
•
port
– COM1 or COM2 (the one to which the printer is connected)
•
code page
– 852
•
controlling codes
– 1B7412
If there are any unexpected signs on the printout in the place of the last digit (for verified balances),
then <CONTROLLING CODES> parameter has to also incorporate code of the UK signs chart:
1B5203
. In such case the <CONTROLLING CODES> parameter setting has to be as follows:
controlling codes -
1B74121B5203
.