background image

OPERATION MANUAL

CC240RF COMPUTE-A-CHARGE

®

WIRELESS CHARGING SCALE

Summary of Contents for CC240RF COMPUTE-A-CHARGE

Page 1: ...OPERATION MANUAL CC240RF COMPUTE A CHARGE WIRELESS CHARGING SCALE ...

Page 2: ... interconnects the display and control unit and the scale platform This wireless scale system has a range of 30 feet 9m CC240RF Specifications Working Load Capacity 110 kg 240 lbs Overload Warning 110 kg 240 lbs Operating Temperature 14 F to 122 F or 10 C to 50 C Operating and Storage Humidity 0 to 95 non condensing Resolution 25 oz 10 g Accuracy 0 05 of reading or 0 25 10 g whichever is greater D...

Page 3: ...NOT STAND WITH YOUR BACK TO THE SCALE PLATFORM Do not turn the display and control unit OFF if connection to the scale platform has been lost LB KG UNITS Momentarily press to toggle units between Imperial and metric units TARE Momentarily press to tare the weight on the platform The weight display returns to zero Display Screens The CC240RF can be used for weighing charging and recovering refriger...

Page 4: ...ed Displays software version of scale platform Figure 4 Count down to connect with the scale plat form on channel 0 Figure 6 Scale platform Automatic Power Off status Figure 1 Displays the software version of the unit Figure 2 Automatic Power Off enabled Press TARE key to change See page 8 for details ...

Page 5: ... figures 1 10 for the screen squence while CC240RF turns on 3 Select the desired unit by pressing the LB KG key 4 Placetheobjectthatistobeweighedontheplatform 6 Gross weight will display 7 When weighing has been completed press and hold the POWER key for 4 seconds to turn the unit OFF Figure 11 Press and hold the POWER key until this message is displayed on the screen Figure 7 Scale platform batte...

Page 6: ... the recovery pathway This allows the flow of refrigerant to the refrigerant recovery unit Recovery Mode Figure B Charge Mode 1 Place the weighing platform on a level rigid surface 2 Press POWER key to turn the unit ON any weight on platform will be set to zero See figures 1 10 for the screen squence while CC240RF turns on 3 Select the desired units by pressing LB KG key 4 Place cylinder on scale ...

Page 7: ...the message in Figure 2 toggles between APO ON and APO OFF If the display and control unit is out of range of the scale platform and it turns off because of the APO the scale platform will remain ON and subsequent connection will not be possible unless the batteries in the platform are removed and re installed after a 60 second delay Danger the recovery cylinder used contains liquid refrigerant Ov...

Page 8: ... rf29 CH x See Fig 4 press TARE the display will change to rf29 OPEn See Fig 12 c When the control and display unit connects to the scale platform and the display enters the weighing mode press and hold the POWER key and then press the LB KG key and release both d In addition to displaying the current channel the display will compare 4 ID s between the control and display unit and the scale platfo...

Page 9: ...ry when the Scale Platform is connected to the Hand Held may cause the system to hang up Remove batteries from both devices if you feel you must remove a battery during operation Low Battery Indication If the system detects a low battery condition the system will turn itself off in a safe condition The display will show the word CELL and either rxxx or Lxxx The r indicates the voltage of the scale...

Page 10: ...ined to be beyond economical repair CPS PRODUCTS Inc HEADQUARTERS 1010 East 31st Street Hialeah Florida 33013 USA Tel 305 687 4121 1 800 277 3808 Fax 305 687 3743 E mail info cpsproducts com www cpsproducts com CPS CANADA 4605 Crysler Ave Niagara Falls Ontario L2E 3V6 Tel 905 358 3124 Fax 905 358 7187 1 866 629 3895 E mail cpscanada bellnet ca CPS PRODUCTS N V Krijgsbaan 241 2070 Zwijndrecht Belgi...

Page 11: ...NOTES ...

Page 12: ... 73 222 www cpsproducts com ...

Reviews: