Communication Protocol
TCP/IP Communications Setup Command Set
CubiScan 25 Service Manual
8 0
Read Gateway Address
This command is used to read the current gateway address setting from the CubiScan 25.
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Read Command
Alpha
(~)
7Eh
3
1
Gateway Address
Command
Alpha
(G)
47h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Read Command
Alpha
(~)
7Eh
3
1
Gateway Address
Command
Alpha
(G)
47h
4
1
Acknowledge
Alpha
(A)
41h
5
7-15
or n
IP Address
Alpha
(0.0.0.0) to
(255.255.255.25
5)
5+n
1
End of Text
Control
(ETX)
03h
6+n
1
Carriage Return
Control
(CR)
0Dh
7+n
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
Pos Len
Description
Type
Range
ASCII
1
1
Start of Text
Control
(STX)
02h
2
1
Read Command
Alpha
(~)
7Eh
3
1
Gateway Address
Command
Alpha
(G)
47h
4
1
Neg. Acknowledge
Alpha
(N)
4Eh
5
1
End of Text
Control
(ETX)
03h
6
1
Carriage Return
Control
(CR)
0Dh
7
1
Line Feed
Control
(LF)
0Ah