Part Replacement
Replacing the Controller Box
CubiScan 25 Service Manual
3 6
7. Move the gate to the left side of the CubiScan 25.
8. Remove the shroud.
9. Use the Phillips screwdriver to remove the two
screws holding one end of the proximity sensor in
place. Refer to
.
10. Unscrew the other end of the proximity sensor cable
from the controller box. Refer to
11. Discard the proximity sensor.
12. Secure the replacement proximity sensor in place
using the screws from step 9.
13. Screw the other end of the proximity sensor into the
controller box. Route the cord so that it does not
interfere with gate movement.
14. Replace the shroud and secure it using the screws
and nuts from steps 5 and 6.
15. Replace the scale plate and secure it using the thumb
screws from step 3. The thumb screws should not be
tightened all the way, they should merely hold the
scale plate in place while still allowing free
movement.
16. Replace the glass platform.
17. Power the CubiScan 25 back on.
Replacing the Controller Box
This section describes how to replace the controller. The
controller box is located behind the touchscreen, on the
right side of the CubiScan 25.
Items Needed
•
3/32'' Allen Wrench
•
11/32'' Nut Driver
•
Phillips Screwdriver
•
5/16'' Wrench
•
Replacement Controller Box
Figure 39
Proximity Sensor
Figure 40
Controller Box Connectors
Screws
Shroud
Gate DB25
Ribbon
Gate
Power
Gate DB9
Ribbon
Encoder
Proximity Sensor