Communication Protocol
CubiScan 25 Command Set
CubiScan 25 Service Manual
7 8
Zero
This command should be issued periodically to force the CubiScan 25 to perform internal
compensations to adjust to changes in temperature and humidity. This command should only be
issued when the measuring field is free of objects! Never issue this command when an object is
present in the measuring field.
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Wgt. Unit Command
Alpha
(#)
23h
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Wgt. Unit Command
Alpha
(#)
23h
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
Pos Len
Description
Type
Range
ASCII